User Manual

EDS94TA10060xxxx EN 1.2 - 03/2010 L 19
9400 Technology applications | Positioning sequence control
Short setup
Step 3: Parameterising the program flow
4.6 Step 3: Parameterising the program flow
The program flow of the positioning sequence control is parameterised in the dialog level
Overview Program flow:
Basic procedure
In the default setting the sequence table contains a small "Positioning program", which
first rotates the axis 360° clockwise and afterwards 360° counter-clockwise.
Proceed as follows to define the desired program flow:
1. Select the program step (1 .... 100) to be edited on the left in the sequence table.
2. Select the action type for the selected program step by clicking it.
If the selected action type provides more than one action, the next free action will be
automatically suggested in the Selection Action Number list field.
Enter a comment on the action (option).
3. Set parameters of the action.
If required, call the corresponding subsequent dialogs.
4. Repeat steps 1 ... 3 until all actions required for the program flow have been
parameterised (see the following sections).
5. Click Back to go back to the Overview dialog level.