Manual
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Parameterisable function blocks
78 L EDS94TA10030xxxx EN 1.2 - 11/2009
5.16.12 VirtualMaster
Is an instance of Function
L_LdVirtualMaster "Virtual master"
Master value source: Virtual master
( 42)
Parameter Possible settings Information
C03565 Virtual master operating mode
0 Continuous operation Lenze setting
1 Inching
2 Handwheel function
C03566 Character string Speed unit
•Read only
C03567 -214748.3647 unit/t 214748.3647 Reference speed
•Read only
• Reference value for selecting
speeds.
C03568/1 -214000.0000 unit/t 214000.0000 Master speed 1
• Initialisation: 1.0000 units/t
C03568/2 -214000.0000 unit/t 214000.0000 Master speed 2
• Initialisation: 1.0000 units/t
C03569/1 0.0000 unit/t 214000.0000 Manual speed CW rotation
• Initialisation: 1.0000 units/t
C03569/2 0.0000 unit/t 214000.0000 Manual speed CCW rotation
• Initialisation: 1.0000 units/t
C03570/1 0.010 s 130.000 Ramp for manual jog
• Initialisation: 1.000 s
C03570/2 0.010 s 130.000 Ramp for continuous operation/
single cycle
• Initialisation: 1.000 s
C03570/3 0.010 s 130.000 Stop ramp
• Initialisation: 1.000 s
C03579 -2147483647 2147483647 State
• Display of the bit-coded output
signal dnState.
C03582 -214748.3647 unit 214748.3647 Speed at the output
•Read only
• Is generated from the speed
signal dnSpeedOut_s.
C03583 -214748.3647 unit 214748.3647 External master speed at the input
•Read only
• Is generated from the speed
signal dnExtMaster_s.