EDS94TA10030xxxx EN 1.2 - 11/2009 L 75
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Parameterisable function blocks
5.16.9 MonitFollowError
C03983 DIS:bPosTeach
• Display of input signal bPosTeach.
0FALSE
1TRUE
C03984 DIS:bBusy
• Display of output signal bBusy.
0 Profile parameters are available.
1 Conversion active, no access to
profile parameters at the moment.
C03985 -2147483647 2147483647 State
• Display of the bit-coded output
signal dnState.
Parameter Possible settings Information
Is an instance of Function
L_LdMonitFollowError Following error monitoring
( 53)
Parameter Possible settings Information
C03960 -214748.3647 unit 214748.3647 Following error at the input
• Display of input signal
dnFollowErrorIn_p in real unit of
the machine.
C03961 Character string Position unit
•Read only
C03963 Following error out of tolerance
•Read only
FALSE Following error smaller than set
switching threshold
TRUE Following error larger than set
switching threshold
C03964 Following error monitoring activated
•Read only
FALSE Deactivated
TRUE Activated