Manual
EDS94TA10030xxxx EN 1.2 - 11/2009 L 63
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Application error messages
5.14 Application error messages
For the output of application-specific error messages an FB instance ApplicationError of the
function block L_DevApplErr is available in the network.
Via the 8 boolean inputs up to 8 different application error messages with
parameterisable module ID, error ID and error response can be activated by the
application.
The first four inputs can be connected to the multiplexer parameters with the desired
tripping signals. The next four inputs are firmly connected to the tripping signals of the
application.
Parameter setting: Tab All parameters
Error message Error ID Error response
1 Free (configurable via C03060/1) 8001 No response
2 Free (configurable via C03060/2) 8002 Error
3 Free (configurable via C03060/3) 8003 Error
4 Free (configurable via C03060/4) 8004 Error
5 Following error 8005 Warning
6 Drive cannot follow 8006 Warning
7 Drive system interrupted 8007 Quick stop by trouble
8 External fault in drive system 8008 Quick stop by trouble
Parameter Lenze setting
C05900 Module ID 999
C05901/1...8 Error ID 1 ... 8 See table above
C05902/1...8 Error response 1 ... 8 See table above
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Application fault 1 C03060/1
FALSE Application fault 2 C03060/2
FALSE Application fault 3 C03060/3
FALSE Application fault 4 C03060/4