Manual
EDS94TA10030xxxx EN 1.2 - 11/2009 L 45
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Operating mode "Electronic gearbox"
5.4.1 Master value processing
[5-5] "Master value processing" function in the signal flow (schematic diagram)
Parameter setting: Tab Application parameters dialog level Overview Electronic
gearbox
Parameter setting: Tab Application parameters dialog level Overview Electronic
gearbox Master value processing
Configuration: Tab FB editor FB GearElectricalShaft
n Master value
o Master value with stretch factor
M
v
Slave
Real master/
Virtual master
v
t
Dv
C03006 = 1
Parameter Lenze setting
Value Unit
C03957 Master value - unit/t
C03000 Stretch factor - numerator 1000000000
C03001 Stretch factor - denominator 1000000000
C03673 Master value with stretch factor - unit/t
Parameter Lenze setting
Value Unit
C03025 Master value - direction of rotation Not inverted
Setpoint inputs of the function Signal configuration
Lenze setting Setpoint input (Multiplexer parameters)
C03000 Stretch factor - numerator C03050/1
C03001 Stretch factor - denominator C03050/2