Instruction Manual

9400 Technology applications | Actuator – speed
Parameter setting & configuration
Parameterisable function blocks
36 L EDS94TA10010xxxx EN 1.1 - 10/2008
C03524 Status "Target setpoint reached"
•Read only
0 Target setpoint not yet reached
1 Target setpoint reached
C03525 0.000 rpm 50000.000 Load reference speed
•Read only
C03526 0.000 rpm 50000.000 Load setpoint speed
•Read only
C03527 0.0000 Unit/t 214000.0000 Reference speed
•Read only
C03528 -214000.0000 Unit/t 214000.0000 Setpoint speed
•Read only
C03529 Character string from AxisData Speed unit
•Read only
C03537 -200.00 % 200.00 External setpoint
Display of input signal
dnExtSpeedSetpoint_n.
C03538 -200.00 % 200.00 Current motor speed
Display of input signal
dnActualMotorSpeed_n.
C03539/1 Invert setpoint
Display of input signal
bInvertSetpoint.
0 Setpoint not inverted
1 Setpoint inverted
C03539/2 Hold setpoint output
Display of input signal
bHoldOutput.
0 Setpoint output enabled
1 Hold setpoint output
C03539/3 Activate stop
Display of input signal bStop.
0 Stop not active
1 Stop requested
C03539/4...7 Activate fixed setpoint 1 ... 8
Display of input signals bJog1 ...
bJog8.
0 Jog input not active
1 Jog input active
C03539/8...11 Activate ramp parameter 1 ... 8
Display of input signals bTi1 ...
bTi8.
0 Ti input not active
1 Ti input active
C03539/12 Load external setpoint
Display of input signal
bLoadExtSpeedSetpoint.
0 Loading not active
1 Load external setpoint
C03539/13 Load motor speed
Display of input signal
bLoadActualMotorSpeed.
0 Loading not active
1 Load motor speed
Parameter Possible settings Information