Instruction Manual

9400 Technology applications | Actuator – speed
Parameter setting & configuration
Parameterisable function blocks
34 L EDS94TA10010xxxx EN 1.1 - 10/2008
4.12 Parameterisable function blocks
This subchapter lists all relevant parameterisable function blocks of the technology
application and the corresponding parameters in alphabetical order.
4.12.1 L_DevApplErr1
4.12.2 L_TbDelay1
Is an instance of Function
L_DevApplErr Error handling
Application error messages
(C 33)
Parameter Possible settings Information
C05900 980 999 Module ID
C05901/1...8 0 65535 Error ID
C05902/1...8 Error response
0None
1Fault
2Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6Information
Is an instance of Function
L_TbDelay Delay of the signal MI_bSpeedCtrlLimited for error handling
Parameter Possible settings Information
C03550 Selection of the edge to be delayed
0 Rising edge Lenze setting
1 Falling edge
2Both edges
C03551 0.000 s 60.000 Delay time
Initialisation: 0.100 s