Owner manual
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02620
630 Firmware 1.37 - 09/2006 L
C02620
C02621
C02622
C02623
C02624
C02638
Parameter | Name:
C02620 | Manual control speed 1
Data type: INTEGER_32
Index: 21955
d
= 55C3
h
Basic function "Manual jog"
Setting range
(min. value | unit | max. value) Lenze setting
0.0000 Unit/s 214748.3647 360.0000 Unit/s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02621 | Manual control speed 2
Data type: INTEGER_32
Index: 21954
d
= 55C2
h
Basic function "Manual jog"
Setting range
(min. value | unit | max. value) Lenze setting
0.0000 Unit/s 214748.3647 720.0000 Unit/s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02622 | Manual control acceleration
Data type: INTEGER_32
Index: 21953
d
= 55C1
h
Basic function "Manual jog"
Setting range
(min. value | unit | max. value) Lenze setting
0.0000 Unit/s² 214748.3647 360.0000 Unit/s²
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02623 | Manual control deceleration
Data type: INTEGER_32
Index: 21952
d
= 55C0
h
Basic function "Manual jog"
Setting range
(min. value | unit | max. value) Lenze setting
0.0000 Unit/s² 214748.3647 1440.0000 Unit/s²
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02624 | Manual control S-ramp time
Data type: UNSIGNED_32
Index: 21951
d
= 55BF
h
Basic function "Manual jog"
Setting range
(min. value | unit | max. value) Lenze setting
0.000 s 10.000 0.100 s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C02638 | Manual control status
Data type: INTEGER_32
Index: 21937
d
= 55B1
h
Status of the basic function "Manual jog" (LS_ManualJog).
Display range
(min. value | unit | max. value)
08
; Read access Write access CINH PLC STOP No transfer COM MOT