Owner manual

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02586
626 Firmware 1.37 - 09/2006 L
C02586
C02587
C02588
C02589
C02590
C02591
Parameter | Name:
C02586 | Starting torque 1
Data type: INTEGER_32
Index: 21989
d
= 55E5
h
Basic function "Brake control"
Setting range
(min. value | unit | max. value) Lenze setting
-21474836.47 Nm 21474836.47 0.00 Nm
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C02587 | Starting torque 2
Data type: INTEGER_32
Index: 21988
d
= 55E4
h
Basic function "Brake control"
Setting range
(min. value | unit | max. value) Lenze setting
-21474836.47 Nm 21474836.47 0.00 Nm
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C02588 | Starting torque source
Data type: UNSIGNED_32
Index: 21987
d
= 55E3
h
Basic function "Brake control"
Selection list
(Lenze setting printed in bold)
0Starting torque 1/2
1 Stopping value
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02589 | Brake closing time
Data type: UNSIGNED_32
Index: 21986
d
= 55E2
h
Basic function "Brake control"
Setting range
(min. value | unit | max. value) Lenze setting
0 ms 60000 100 ms
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02590 | Brake opening time
Data type: UNSIGNED_32
Index: 21985
d
= 55E1
h
Basic function "Brake control"
Setting range
(min. value | unit | max. value) Lenze setting
0 ms 60000 100 ms
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02591 | Waiting time- status monitoring
Data type: UNSIGNED_32
Index: 21984
d
= 55E0
h
Basic function "Brake control"
Setting range
(min. value | unit | max. value) Lenze setting
0 ms 60000 100 ms
; Read access ; Write access CINH PLC STOP No transfer COM MOT