Owner manual
L Firmware 1.37 - 09/2006 609
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01191
C01191
C01192
C01193
C01194
C01195
Parameter | Name:
C01191 | Temperature for spec. characteristic
Data type: UNSIGNED_32
Index: 23384
d
= 5B58
h
The special thermal sensor characteristic is selected by setting C01190="1"
Setting range
(min. value | unit | max. value)
0 °C 255
Subcodes Lenze setting Information
C01191/1 25 °C Value 1 for spec. thermal sensor characteristic
C01191/2 150 °C Value 2 for spec. thermal sensor characteristic
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C01192 | Resistor for spec. characteristic
Data type: UNSIGNED_32
Index: 23383
d
= 5B57
h
The special thermal sensor characteristic is selected by setting C01190="1"
Setting range
(min. value | unit | max. value)
0 Ohm 30000
Subcodes Lenze setting Information
C01192/1 1000 Ohm Value 1 for spec. thermal sensor characteristic
C01192/2 2225 Ohm Value 2 for spec. thermal sensor characteristic
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C01193 | Motor temp. feedback system
Data type: UNSIGNED_16
Index: 23382
d
= 5B56
h
Selection of feedback system for motor temperature detection.
Selection list
(Lenze setting printed in bold)
0 Speed feedback
1Resolver X7
2Encoder X8
3 Encoder module in MXI1
4 Encoder module in MXI2
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C01194 | Motor operating temperature
Data type: INTEGER_32
Index: 23381
d
= 5B55
h
Setting range (min. value | unit | max. value) Lenze setting
1 °C 200 140 °C
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C01195 | Influence winding I²xt mon.
Data type: UNSIGNED_32
Index: 23380
d
= 5B54
h
I
2
xt motor monitoring: Influence of the winding temperature
• By setting "0 %" the time constant for the winding is not considered and the thermal model is only calculated
with the time constant set for the housing/steel plates.
Setting range
(min. value | unit | max. value) Lenze setting
0 % 100 0 %
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT