Owner manual

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00375
578 Firmware 1.37 - 09/2006 L
C00375
C00376
C00377
Parameter | Name:
C00375 | CAN SDO client Rx identifier
Data type: BITFIELD_32
Index: 24200
d
= 5E88
h
Identifier which serves to reach the assigned SDO client.
Setting bit 31 (0x8nnnnnnn) deactivates the corresponding SDO client channel (see DS301V402).
The client channels need not be parameterised right now. Their functionality will only be required when using
the Gateway services.
Value is bit-coded: Information
Bit 0 COB-ID bit 0 Bit 0 ... 10: COB-ID
Bit 11 ... 30: Reserved
Bit 31: SDO invalid
... ...
Bit 31 SDO invalid
Subcodes Lenze setting Information
C00375/1 0x80000000 SDO client channel 1 RX ... 10 RX
C00375/...
C00375/10
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00376 | CAN SDO client Tx identifier
Data type: BITFIELD_32
Index: 24199
d
= 5E87
h
Identifier with which the assigned SDO client is able to transmit.
Setting bit 31 (0x8nnnnnnn) deactivates the corresponding SDO client channel (see DS301V402).
The client channels need not be parameterised right now. Their functionality will only be required when using
the Gateway services.
Value is bit-coded: Information
Bit 0 COB-ID bit 0 Bit 0 ... 10: COB-ID
Bit 11 ... 30: Reserved
Bit 31: SDO invalid
... ...
Bit 31 SDO invalid
Subcodes Lenze setting Information
C00376/1 0x80000000 SDO client channel 1 TX ... 10 TX
C00376/...
C00376/10
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00377 | CAN SDO server node address
Data type: UNSIGNED_8
Index: 24198
d
= 5E86
h
Node address of the server with which the SDO client communicates via the selected client channel.
The client functionality need not be activated.
Activation of the CAN SDO client channel requires an entry (see DS301V402).
Setting range
(min. value | unit | max. value)
1 127
Subcodes Lenze setting Information
C00377/1 1 Remote server node address for SDO client channel 1 ...
10
C00377/...
C00377/10
; Read access ; Write access CINH PLC STOP No transfer COM MOT