Parameter reference
Parameter list | C00120
C00120
C00121
C00122
C00123
C00126
C00127
Parameter | Name:
C00120 | Mot. overload protection (I²xt)
Data type: UNSIGNED_32
Index: 24455
d
= 5F87
h
Threshold for I
2
x t disconnection
Disconnection is carried out if the thermal motor load (C00066
) is higher than the set threshold.
A 100 % thermal motor load corresponds to a permanently flowing rated motor current
Setting range
(min. value | unit | max. value) Lenze setting
0 % 200 105 %
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00121 | Motor temp. warning threshold
Data type: UNSIGNED_32
Index: 24454
d
= 5F86
h
Temperature threshold for motor temperature advance warning
The reaction for reaching the threshold can be selected in C00584
.
Setting range
(min. value | unit | max. value) Lenze setting
0 °C 150 120 °C
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00122 | Heatsink temp. warn. threshold
Data type: UNSIGNED_32
Index: 24453
d
= 5F85
h
Temperature threshold for heatsink temperature advance warning
The reaction for reaching the threshold can be selected in C00582
.
Setting range
(min. value | unit | max. value) Lenze setting
C8585 °C
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00123 | Device util. warning threshold
Data type: UNSIGNED_32
Index: 24452
d
= 5F84
h
Adjustable threshold for I x t advance warning
The advance warning is sent if the controller load (C00064
) is higher than the set threshold.
The reaction for reaching the threshold can be selected in C00604
.
Setting range
(min. value | unit | max. value) Lenze setting
0 % 100 90 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00126 | CPU temp. warning threshold
Data type: UNSIGNED_32
Index: 24449
d
= 5F81
h
Temperature threshold for advance warning of CPU temperature on the control card
The reaction for reaching the threshold can be selected in C00589
.
Setting range
(min. value | unit | max. value) Lenze setting
C8570 °C
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00127 | Mot. overload warning threshold
Data type: UNSIGNED_32
Index: 24448
d
= 5F80
h
Adjustable threshold for I
2
x t advance warning
The advance warning is sent if the thermal motor load (C00066
) is higher than the set threshold.
The reaction for reaching the threshold can be selected in C00606
.
Setting range
(min. value | unit | max. value) Lenze setting
0 % 200 100 %
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT