Owner manual
L Firmware 1.37 - 09/2006 517
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
DFIN (MXI2): Z-/Z track error [0x00aa0002]
DFIN (MXI2): Enable/lamp control signal error [0x00aa0003]
DFIN (MXI2): Supply cannot be corrected anymore [0x00aa0004]
DFOUT (MXI2): Maximum frequency reached [0x00aa0005]
CAN module (MXI2): Bus-off [0x00ac0000]
Response (Lenze setting printed in bold) Setting: C14040 (; Adjustable response)
; None System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of the signal cable for track Z.
• Check signal cable for track Z.
•Check encoder.
Response (Lenze setting printed in bold) Setting: C14041 (; Adjustable response)
; None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of the signal cable for the
"Enable" signal or no "Enable" signal available.
• Check signal cable for "Enable" signal.
•Check encoder.
Response (Lenze setting printed in bold) Setting: C14042 (; Adjustable response)
; None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI2: The
encoder voltage controlled by the digital frequency input
has reached the voltage limit.
Check encoder.
Response (Lenze setting printed in bold) Setting: C14080 (; Adjustable response)
; None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI2: Limit
frequency at the digital frequency output reached.
• The digital frequency has reached the limit value set
in C014053
.
Check set limit value.
Response (Lenze setting printed in bold) Setting: C14595 (; Adjustable response)
; None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning : Information
Cause Remedy
CANopen communication module in MXI2: "Bus-off"
state
• Too many faulty telegrams received.
• Cable defective (e.g. loose contact).
• Two nodes with the same ID.
• Remove fault (e.g. EMC).
• Remove loose contact, screw down adapter.
• Assign different node IDs.