Electronic nameplate: Unknown encoder signal [0x007b0033]
Internal communication error (DMA) [0x007b0034]
Internal communication error (MCTRL host) [0x007b0036]
Invalid PLC configuration [0x007b0037]
Motor parameter identification has been cancelled [0x007b0038]
Electronic nameplate: Data out of parameter limits [0x007b0039]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
The connected motor with feedback is not supported by
the controller firmware.
Check drive dimensioning.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Internal error. Please contact Lenze.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Internal error. Please contact Lenze.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
An invalid control configuration has occurred. Load other application.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The motor current during identification was too high. The motor must not move during identification.
Check motor parameters
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
The motor parameters of the electronic nameplate are
out of the limit values of the controller and therefore
cannot be accepted.
Please contact Lenze.