Owner manual
L Firmware 1.37 - 09/2006 349
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | "Synchronism" mode"
12.3.5.4 Master value trimming
[12-30] "Master value trimming" function in the signal flow (schematic diagram)
This function serves to adjust the master value.
r Parameter setting: Tab Application parameter Dialog level Overview Synchronism
Master value trimming
r Configuration: Tab FB editor FB Trimming
n Master value with clutch
o Master value with trimming
M
v
Slave
Real master/
Virtual master
C03006 = 0
v
t
Dj
Dj Dj
TP TP
Parameters Lenze setting
Value Unit
C03674 Master value with clutch - Unit
C03026 Activate trimming Deactivated
C03676 Adjustable range 0.0000 Unit/t
C03685 Positioning mode 0
C03686 Deactivation mode 1
C03688/1 Positive speed 1000.0000 Unit/t
C03688/2 Negative speed 1000.0000 Unit/t
C03691/1 Acceleration ramp 0.500 s
C03691/2 Deceleration ramp 0.500 s
C03691/3 Stop ramp 1.000 s
C03723 Master value with trimming - Unit
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Start trimming C03058/15
C03026 Activate trimming C03058/16
FALSE Set trimming setpoint to 0 C03058/17