Owner manual

L Firmware 1.37 - 09/2006 335
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | Assignment of the I/O terminals
12.3.2 Assignment of the I/O terminals
12.3.2.1 Setpoint and control signals
The following tables contain the Lenze assignment of the analog and digital inputs for the
technology application "Synchronism".
Analog inputs
Digital inputs
Terminal X3 Signal (Lenze setting)
AI1-
AI1+
-
AI2-
AI2+
-
I/O terminalsAnalog inputs (C 117)
Terminal X5 Signal (Lenze setting)
DI1 Quick stop
If DI1 is set to LOW level, the drive is decelerated to standstill within the deceleration
time set for the quick stop function independent of the setpoint selection.
If the quick stop function is deactivated, the drive is led to the selected setpoint again via
the set acceleration time.
Basic drive functions
Quick stop (C 152)
DI2 Connection of reference switch/touch probe sensor for tool synchronisation
DI3 Connection of touch probe sensor for master value synchronisation
DI4 Close clutch
DI5 Reset error
By means of a LOW-HIGH edge an existing error status can be reset if the cause of the
fault is removed.
DI6 Start trimming
DI7 -
DI8 -
I/O terminalsDigital inputs (C 123)
A1+
A1-
A1-
A1R
A2+
A2-
GI
RFR
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8