Owner manual

L Firmware 1.37 - 09/2006 309
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Operating mode "Electronic gearbox"
12.2.5.1 Master value processing
[12-13] "Master value processing" function in the signal flow (schematic diagram)
r Parameter setting: Tab Application parameter Dialog level Overview Electronic
gearbox
r Parameter setting: Tab Application parameter Dialog level Overview Electronic
gearbox Master value processing
r Configuration: Tab FB editor FB GearElectricalShaft
n Master value
oMaster value with stretch factor
M
v
Slave
Real master/
Virtual master
v
t
Dj
C03006 = 0

Parameters Lenze setting
Value Unit
C03957 Master value - Unit/t
C03000 Stretch factor - numerator 1000000000
C03001 Stretch factor - denominator 1000000000
C03673 Master value with stretch factor - Unit/t
Parameters Lenze setting
Value Unit
C03025 Master value - direction of rotation Not inverted
Setpoint inputs of the function Signal configuration
Lenze setting Setpoint input (Multiplexer parameters)
C03000 Stretch factor - numerator C03050/1
C03001 Stretch factor - denominator C03050/2