5 Function blocks
5.209 L_WndStopCtrl - stop controller
650
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
Parameters
dnLineSpeed_n
DINT
Material speed setpoint in [%]
100 % maximum material speed (dwReferenceLineSpeed)
dwRefDiameter
DWORD
Reference diameter for pre-switch-off and switch-off signal in [μm]
• 1000 μm 1 mm; 1000000 μm 1m
Internal limitation to 10 m
Identifier/data type Value/meaning
dwLengthToRef
DWORD
Residual length until reaching the reference value in [mm]
Internal limitation to 2000 km
dwTimeToRef
DWORD
Residual runtime until reaching the reference value in [s]
The calculation depends on C04880, either on the basis of the material speed set-
point or the maximum material speed.
This value is only calculated at every 2. call of the FB (alternating with
dwStopLength).
dwStopLength
DWORD
Change in length during the braking phase in [mm]
This value is only calculated at every 2. call of the FB (alternating with
dwTimeToRef).
bStartDec
BOOL
Control signal for starting the braking process
TRUE Pre-switch-off length reached.
bRefReached
BOOL
Control signal for triggering the limit stop
TRUE Reference length dwRefLength reached.
Parameter Possible settings Info
C04880 Reference value = Stop length of reference value
Reference value for the rated de-
celeration time dwNominalTif
• Initialisation: maximum material
speed
0 Maximum material speed
(dwReferenceLineSpeed)
1 Material speed setpoint
(dnLineSpeed_n)