User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 63
3 Working with the FB editor
3.4 Creating/reconfiguring the interconnection
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to configure a new user code:
1. Go to the Assign User Code dialog box and press the New button.
•The Create user code dialog box for configuring a new user code is displayed.
2. Configure the properties of the user code.
See the following section "Properties of a user code
".
3. Press OK.
•The Create user code dialog box is closed and the newly configured user code is listed in
the Assign User Code dialog box.
Properties of a user code
Input field Information
Code Code number
• The next free code number is already entered into the input field.
• The range of 3000 ... 9999 is available for user codes.
• The code number must not already be allocated within the application.
Access rights Selection whether only read or also write access to user code should be pos-
sible.
For a user code with write access, the following properties can be configured
in addition:
Depends on
controller inhibit
Set a checkmark in this control field if the user code
should only be parameterised when the controller is
inhibited.
Dependent upon
PLC stop
Set a checkmark into this control field if the user code
should only be parameterised when the application
is stopped.
Keypad confirmation
via SH-PRG
Set a checkmark into this control field if the parame-
terisation of the user code should be confirmed using
the keypad.
Number of subcodes Number of subcodes (0 ... 255)
If subcodes have been defined, the initialisation values and display texts
are configured in the Initialisation values dialog box, which you open via
the Subcodes... button.
Unit Optional text
• The unit is displayed in the »Engineer« parameter list and in the keypad
for the user code.
Scaling Selection whether the user code is to be displayed with a linear value or a se-
lection list.
Depending on the selection, the other possible settings for the user code
change.