5.178 L_TbMaskOut - zone masking
This FB masks up to four parameterisable blocking zones within a continuous signal characteristic.
The definition of the upper and lower limits of the blocking zones is effected by specifying the
mean value and the half width of the respective zone.
The FB can be generally used (no measuring system reference).
Inputs
Outputs
Parameter
Function library: LenzeToolbox
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
bEnable
BOOL
Activate zone masking
FALSE The FB is deactivated.
The input signal is shown 1:1 at the output dnOutput_n.
TRUE The FB is activated.
A zone masking of the input signal according to the parameteri-
sed blocking zones is carried out.
dnInput_n
DINT
Scaled input signal in [%]
Identifier/data type Value/meaning
dnOutput_n
DINT
Scaled output signal in [%]
If the FB is activated, the output signal is beyond the blocking zones.
bLimitActive
BOOL
Status signal "Limitation active"
TRUE The input signal is within a blocking zone and is limited to the corre-
sponding boundary value of the zone.
Parameter Possible settings Information
C04110/1...4 0.00 % 200.00 Mean value of blocking zones 1 ... 4
Initialisation: 0.00 %
C04111/1...4 0.00 % 100.00 Half width of blocking zones 1 ... 4
Initialisation: 0.00 %