5 Function blocks
5.162 L_TbCount - up/downcounter
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.162 L_TbCount - up/downcounter
This FB is a digital up/downcounter with adjustable limitation.
Under C04005 you can select if the counter is to be stopped or reset automatically when rea-
ching the limitation.
Inputs
Outputs
Function library: LenzeToolbox
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
bClockUp
BOOL
Upcounter
FALSETRUE Increase counter by "1".
bClockDown
BOOL
Downcounter
FALSETRUE Reduce counter by "1".
bLoadStartValue
BOOL
Accept starting value
This input has the highest priority.
TRUE The starting value specified via dnStartValue is loaded into the coun-
ter.
dnStartValue
DINT
Starting value
dnReferenceValue
DINT
Comparison value
Identifier/data type Value/meaning
dnActualCount
DINT
Current counter content
bCountEQReference
BOOL
Result of the comparison of current counter content and comparison value
TRUE |dnActualCount| |dnReferenceValue|