User guide
5 Function blocks
5.155 L_TbAbs - absolute value
548
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.155 L_TbAbs - absolute value
This function block converts a bipolar signal into a unipolar signal, i.e. the absolute value of the in-
put signal is generated.
Inputs
Outputs
Function library: LenzeToolbox
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
dnIn
DINT
Input signal
Identifier/data type Value/meaning
dnOut
DINT
Output signal
GQ2XWGQ,Q