User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 547
5 Function blocks
5.154 L_Tb8SelectWord - 1-out-of-8 selector (for data type "WORD")
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.154 L_Tb8SelectWord - 1-out-of-8 selector (for data type "WORD")
This FB connects one of eight input signals of "WORD" type through to the output.
The input is selected via the input dwSelect.
Inputs
Outputs
Function library: LenzeToolbox FB is available as of library V02.05.xx.xx!
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
wIn1
...
wIn8
WORD
Input signal 1 ... 8
dwSelect
DWORD
Selection of the input signal for the output to wOut
00
1 wIn1
2 wIn2
3 wIn3
4 wIn4
5 wIn5
6 wIn6
7 wIn7
8 wIn8
> 8 0
Identifier/data type Value/meaning
wOut
WORD
Output signal
Z2XW
Z,Q
Z,Q
Z,Q
Z,Q
Z,Q
Z,Q
Z,Q
GZ6HOHFW
Z,Q
/B7E6HOHFW:RUG