User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 533
5 Function blocks
5.142 L_SdSwitchPoint - position switch points
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
Parameter
Identifier/data type Value/meaning
bSwitch1
BOOL
Position switch point 1
TRUE The current position (dnPosIn_p) is inside the switching range defi-
ned via C04397/1 and C04398/1.
bSwitch2
BOOL
Position switch point 2
TRUE The current position (dnPosIn_p) is inside the switching range defi-
ned via C04397/2 and C04398/2.
bSwitch3
BOOL
Position switch point 3
TRUE The current position (dnPosIn_p) is inside the switching range defi-
ned via C04397/3 and C04398/3.
bSwitch4
BOOL
Position switch point 4
TRUE The current position (dnPosIn_p) is inside the switching range defi-
ned via C04397/4 and C04398/4.
bSwitch5
BOOL
Position switch point 5
TRUE The current position (dnPosIn_p) is inside the switching range defi-
ned via C04397/5 and C04398/5.
bSwitch6
BOOL
Position switch point 6
TRUE The current position (dnPosIn_p) is inside the switching range defi-
ned via C04397/6 and C04398/6.
bSwitch7
BOOL
Position switch point 7
TRUE The current position (dnPosIn_p) is inside the switching range defi-
ned via C04397/7 and C04398/7.
bSwitch8
BOOL
Position switch point 8
TRUE The current position (dnPosIn_p) is inside the switching range defi-
ned via C04397/8 and C04398/8.
Parameter Possible settings Information
C04395/1...8 Status of switching range 1 ... 8
•Read only
0Switch off
1Switch on
C04396
As of library V02.02.xx.xx
String of digits Position unit
•Read only
C04397/1...8 -214748.3647 Unit 214748.3647 Switch-on position - switching range
1...8
C04398/1...8 -214748.3647 Unit 214748.3647 Switch-off position - switching range
1...8
C04399/1...8 Enable - switching range 1 ... 8
0 Switching range not enabled
1 Switching range enabled