5 Function blocks
5.140 L_SdSpeedSet - setpoint ramp generator
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C04228 -214000.0000 Unit/t 214000.0000 Setpoint speed
•Read only
C04229 String from AxisData Speed unit
•Read only
C04237 -200.00 % 200.00 External setpoint
•Display of the
dnExtSpeedSetpoint_n input sig-
nal.
C04238 -200.00 % 200.00 Current motor speed
•Display of the
dnActualMotorSpeed_n input sig-
nal.
C04239/1 Reverse setpoint
•Display of the bInvertSetpoint in-
put signal.
0 Setpoint not inverted
1 Setpoint inverted
C04239/2 Hold setpoint output
•Display of the bHoldOutput input
signal.
0 Setpoint output enabled
1 Hold setpoint output
C04239/3 Stop
•Display of the bStop input signal.
0 Stop not active
1 Stop requested
C04239/4...7 Jog input 1 ... 8
•Display of the bJog1 ... bJog8 input
signals.
0 Jog input not active
1 Jog input active
C04239/8...11 Ti input 1 ... 8
•Display of the bTi1 ... bTi8 input si-
gnals.
0 Ti input not active
1 Ti input active
C04239/12 Load external setpoint
•Display of the
bLoadExtSpeedSetpoint input sig-
nal.
0 Loading not active
1 Load external setpoint
C04239/13 Load motor speed
•Display of the
bLoadActualMotorSpeed input si-
gnal.
0 Loading not active
1 Load motor speed
Parameter Possible settings Information