User guide
5 Function blocks
5.130 L_SdMotorPot - motor potentiometer
490
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.130.1 Acceleration and deceleration time
The acceleration and deceleration time can be parameterised independently of each other in
C04361/1 and C04361/2 and relate to a change in the output value dnOut_n by 100 %:
[5-100] Definition of the acceleration and deceleration time
5.130.2 Control signals
C04369 Bit coded: Status
• Bits that are not itemised are re-
served for future extensions.
bits5 Starting value loaded is limited
bits6 Upper limit value reached
bits7 Lower limit value reached
bits19 Lower limit value > upper limit value
bits31 General error
Parameter Possible settings Information
C04361/1: acceleration time
C04361/2: deceleration time
dnOut_n
t
bDown
t
bUp
t
+200 %
0%
C04361/1
-200 %
+100 %
C04361/2
C04361/1
bUp bDown bDisable bLoadStartValue Function
FALSE FALSE FALSE FALSE dnOut_n remains unchanged.
TRUE FALSE FALSE FALSE Increase output value
With the acceleration time set in
C04361/1, dnOut_n is increased until
the upper limit value has been rea-
ched (C04360/1).
FALSE TRUE FALSE FALSE Decrease output value
With the deceleration time set in
C04361/2, dnOut_n is decreased un-
til the lower limit value has been rea-
ched (C04360/2).
TRUE TRUE FALSE FALSE dnOut_n remains unchanged.