Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.130 L_SdMotorPot - motor potentiometer
This FB replaces a hardware motor potentiometer and can be used as an alternative setpoint source
controlled via two inputs.
The signal output is effected via a ramp function generator with linear ramps.
The acceleration and deceleration time and the upper and lower limit value can be parameteri-
sed independently of each other.
The behaviour after mains switching can be parameterised; in the Lenze setting the last output
value before the mains are switched off is re-established.
The behaviour in the case of deactivation of the motor potentiometer function can also be pa-
rameterised.
Inputs
Function library: LenzeServoDrive FB is available as of library V02.04.xx.xx!
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Required retain memory: 212 bytes
Identifier/data type Information/possible settings
bUp
BOOL
Increase output value
TRUE With the acceleration time set in C04361/1, dnOut_n is increased
until the upper limit value has been reached (C04360/1).
•If the input bDown is set to TRUE at the same time, dnOut_n is not
changed.
bDown
BOOL
Decrease output value
TRUE With the deceleration time set in C04361/2, dnOut_n is decreased
until the lower limit value has been reached (C04360/2).
If the input bUp is set to TRUE at the same time, dnOut_n is not
changed.
bDisable
BOOL
Deactivate motor potentiometer function
This input has the second highest priority after bLoadStartValue.
The behaviour of the output value dnOut_n in the case of deactivation can be se-
lected in C04362; in the Lenze setting the last output value is maintained.
TRUE Motor potentiometer function is deactivated.
bLoadStartValue
BOOL
Load motor potentiometer with starting value
This input has the highest priority.
TRUE dnOut_n is set to the starting value dnStartValue_n.
If the starting value is beyond the limit values parameterised, the
output value dnOut_n is limited to the corresponding limit value.