User guide

5 Function blocks
5.114 L_PosSequencer - sequence control
446
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.114.3.7 Action type "Waiting"
25 actions of type "Waiting" are available for the insertion into the program flow.
The sequence step is only processed after the waiting time has expired or when the selected
bit 1 ... 32 of the input signal dwDigitalInputs has the selected signal state ("1" or "2") at the time
of processing.
Action call (entry in the sequence table)
with action number xxx = 001 ... 025
Parameter
The available actions 1 ... 25 are indicated via the subcodes 1 ... 25.
Waiting time Input Function
C04571 C04572
0
(deactivated)
0
(deactivated)
Sequence step is processed immediately (default setting).
> 0 [s] 0
(deactivated)
After the waiting time has expired, the sequence step will be processed.
> 0 [s] 1 ... 32 The sequence step will be processed when the input for the waiting time has the set
state, but no later than after the set waiting time has elapsed.
0
(deactivated)
1 ... 32 If the input for the waiting function has the set state, the sequence step will be pro-
cessed.
Parameter Possible settings Information
C04570/1...25 Text Comment on waiting step
Option for description of the func-
tion for keypad/HMI.
C04571/1...25 0 Waiting time is deactivated. Waiting time
> 0 Waiting time in [s]
C04572/1...25 Input for waiting function
0 Input is deactivated.
1 Sequencer input 1
(Bit 0 of dwDigitalInputs)
2 Sequencer input 2
(Bit 1 of dwDigitalInputs)
... ...
32 Sequencer input 32
(Bit 31 of dwDigitalInputs)
C04573/1...50 Signal state for waiting function
Only when the input for the wai-
ting function has adopted this
state, the sequence step will be
processed.
0 Sequence step when bit state is "0"
1 Sequence step when bit state is "1"
7xxx