User guide

5 Function blocks
5.114 L_PosSequencer - sequence control
442
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.114.3.3 Action type "Switching"
In order to switch digital output signals 25 actions of type "Switching" are available.
Each action can set two selectable bits of the output signal dwDigitalOutputs to "0" or "1" inde-
pendently of each other.
Action call (entry in the sequence table)
with action number xxx = 001 ... 025
Parameter
The available actions 1 ... 25 are indicated via the subcodes 1 ... 25.
Parameter Possible settings Information
C04520/1...25 Output for A switching
0 Switching is deactivated.
1 Sequencer output 1
(Bit 0 of dwDigitalOutputs)
2 Sequencer output 2
(Bit 1 of dwDigitalOutputs)
... ...
32 Sequencer output 32
(Bit 31 of dwDigitalOutputs)
C04521/1...25 Signal state for A switching
0Set bit to "0".
1 Set bit to "1".
C04522/1...25 Output for B switching
0 Switching is deactivated.
1 Sequencer output 1
(Bit 0 of dwDigitalOutputs)
2 Sequencer output 2
(Bit 1 of dwDigitalOutputs)
... ...
32 Sequencer output 32
(Bit 31 of dwDigitalOutputs)
C04523/1...25 Signal state for B switching
0Set bit to "0".
1 Set bit to "1".
2xxx