User guide

5 Function blocks
5.114 L_PosSequencer - sequence control
438
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.114.3 Action types available for creating the positioning program
The program flow of the multi-purpose positioning is selected according to a sequence table which
can contain up to 100 references to "actions".
An action comprises a clear functionality which is described with a few parameters.
Different action types are available which serve to implement, for instance, program branching,
switching operations, waiting times and counters.
Each action type provides a certain number of actions which can be parameterised individually.
One action can be called from several positions in the sequence table.
After an action has been processed, the action in the next step of the sequence table is auto-
matically processed unless it is jumped to another step in the sequence table due to a branch.
One action can be maximally processed per computing cycle.
The sequence table and the actions are displayed by parameters (codes with subcodes).
Action calls are entered into the sequence table using a decimal number which contains the ac-
tion type and the action number .
Overview
Detailed information of the action types can be found in the following subchapters.
Action Action type
Action number
Number of available
actions
Parameter range
(first instance)
Program end 0 000 1 -
Positioning 1 001 ... 050 50 C04510 ... C04516
Switching 2 001 ... 025 25 C04520 ... C04523
Branching 3 001 ... 025 25 C04530 ... C04532
Variable branching 4 001 ... 005 5 C04540 ... C04559
Homing 5 000 1 -
Waiting 7 001 ... 025 25 C04570 ... C04573
Counter setting 8 001 ... 010 10 C04580 ... C04582
Counting 9 001 ... 025 25 C04590 ... C04593
Stand-by 10 001 ... 005 5 C04600 ... C04602
1
n
2
0
1
0
Set
00 1
Standby End
3
4
2
10