_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
bEnableFollower
BOOL
Enable signal for setpoint follower
This output is intended for the enable of a setpoint follower during a stand-by
program step.
Connect this output, if required, with the input bEnable of the corresponding set-
point follower (SB LS_SpeedFollower, SB LS_TorqueFollower or
SB LS_PositionFollower).
Display parameter: C04690/10
FALSE No enable since the basic function "Positioning" is active.
TRUE Enable is possible since stand-by program step is active.
dwDigitalOutputs
DWORD
Sequencer outputs 1 ... 32 (bit coded)
The sequencer outputs can be set to "0" or "1" by means of the "Switching" action
type during the runtime of the positioning program.
For the transmission of individual control signals a DWORD-to-BOOL converter
can be connected to this input.
Display parameter: C04693/2
bits0 Sequencer output 1
bits1 Sequencer output 2
... ...
bits31 Sequencer output 32
Identifier/data type Value/meaning