User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 429
5 Function blocks
5.113 L_PosProfileTable - profile data record management (simple)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.113.5 Monitoring for counter overflow
This function extension will be available from library V2.02!
If the machine parameters transferred to the FB via the AxisData input are changed afterwards (e.g.
the gearbox factors), this may cause a counter overflow when the speed, acceleration, and position
values defined via parameters are converted from the real unit to the internal unit.
The FB causes a corresponding error message in case of an internal counter overflow due to a chan-
ged measuring system:
Error number Error message in the logbook Response
61736966 0x3AE0806 L_PosProfileTable:int.pos. overflow (LS_DriveInterface) Error
61737222 0x3AE0906 L_PosProfileTable:int.pos. overflow (L_SdSetAxisData) Error
61735942 0x3AE0406 L_PosProfileTable:int.speed overflow (LS_DriveInterface) Error
61736198 0x3AE0506 L_PosProfileTable:int.speed overflow (L_SdSetAxisData) Error
61735430 0x3AE0206 L_PosProfileTable:int.accel. overflow (LS_DriveInterface) Error
61735686 0x3AE0306 L_PosProfileTable:int.accel. overflow (L_SdSetAxisData) Error