User guide

5 Function blocks
5.112 L_PosProfileInterface - profile data interface
414
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.112 L_PosProfileInterface - profile data interface
This FB provides a profile data record for the SB LS_Positioner.
Inputs
Function library: LenzePositioning
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
dwPositioningMode
DWORD
Positioning mode
For absolute positioning, the home position must be known!
Not all positioning modes are available in every traversing range!
Positioning modes
( 416)
1Absolute
2Absolute TP
5Relative
6Relative TP
7 Speed
8 Speed TP
11 Absolute CW (modulo)
12 Absolute CW TP (modulo)
13 Absolute CCW (modulo)
14 Absolute CCW TP (modulo)
15 Absolute ShortestWay (modulo)
16 Absolute ShortestWay TP (modulo)
dnTargetPosition_p
DINT
Target position in [inc]
dnSpeed_s
DINT
Speed
Entry as speed
Scaling: 2
26
15000 [rpm]
/B3RV3URILOH,QWHUIDFH
GQ7DUJHW3RVLWLRQBS
GZ3RVLWLRQLQJ0RGH
1H[W3URILOH'DWD
1H[W733URILOH'DWD
GQ73:LQGRZ6WDUW
GQ73:LQGRZ(QG
GZ73&RQILJ
GZ3URILOH1XPEHU
3URILOH'DWD
GQ6SHHGBV
GQ$FFHOHUDWLRQB[
GQ'HFHOHUDWLRQB[
GQ-HUN
GQ(QG6SHHGBV
GZ-HUN0RGH
GQQG-HUN