5.103 L_PosDecoderStateSequencer - status signals of the sequence control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.103 L_PosDecoderStateSequencer - status signals of the sequence control
This FB decodes the status output signal dnState of FB LS_PosSequencer into individual boolean sta-
tus signals for further use in the FB interconnection.
The functionality corresponds to a converter "DINTBOOL", but the boolean outputs of this FB
have the same names according to their meaning.
Inputs
Outputs
The boolean outputs have the following meaning when the value is TRUE:
Function library: LenzePositioning Do not use FB for new developments!
Replacement by L_PosSequencerStateDecoder
.
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
dnState
DINT
Input for the bit coded status signal of the sequence control.
Connect this input with the output of the same name of the FB L_PosSequencer
.
( 430)
Bit* Identifier Meaning in case of TRUE
Status messages:
16 bReady Positioning program ready to start/program end reached.
17 bStarted Positioning program is running.
18 bPause Positioning program is started, pause is active.
19 bStop Positioning program is stopped.
20 bReset Positioning program is reset.
Error messages:
22 bWatchDogActive "Watchdog" monitoring function for positioning has been activated.
15 bErrActive Error is active.
25 bErrBranch Wrong value at branch input.
* Relating to the input signal dnState.