User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 367
5 Function blocks
5.98 L_LdSyncOperation - master value connection
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C05094 -214748.3647 Unit 214748.3647 Position x at the input (master positi-
on)
•Display of the dnXPosIn_p input
signal in the real unit of the ma-
chine.
C05095 -214748.3647 Unit 214748.3647 Trimming X
•Display of the dnXOffset_p input
signal in the real unit of the ma-
chine.
C05096 -214748.3647 Unit/t 214748.3647 Speed X at the output
Display of the resulting master
speed
Calculated from the speed signal
dnXSpeedOut_s.
C05097 -214748.3647 Unit/t 214748.3647 Speed Y at the output
Display of the resulting setpoint
speed
Calculated from the speed signal
dnYSpeedOut
_s.
C05098 -214748.3647 Unit 214748.3647 Position X at the output
(resulting master position)
Display of the output signal
dnXActPos_p in the real unit of the
machine.
C05099 -214748.3647 214748.3647 Status
Display of the bit-coded output si-
gnal dnState.
Parameter Possible settings Information