User guide
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 363
5 Function blocks
5.98 L_LdSyncOperation - master value connection
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.98 L_LdSyncOperation - master value connection
This FB implements synchronism between a master drive and a slave drive:
• Drift-free synchronism between master drive and slave drive (modulo measuring systems) with
different types of couplings.
• Additional in-cycle compensation of angular trimming in the master measuring system (x off-
set).
Tip!
There are two other FB for synchronous operations:
•The L_LdConvAxisV
FB generates the speed setpoint for the following axis from the mas-
ter speed instead of the master position, as this FB does.
• Like this FB, the L_LdLinearCoupling
FB accepts an x position as the master value, but ge-
nerates a setpoint position for the following axis in addition to the setpoint speed.
Inputs
Function library: LenzeLineDrive
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
bEnable
BOOL
Activate function
FALSE Function has been deactivated.
•The dnXSpeedOut_s and dnXActPos_p outputs continue to follow
the dnXPosIn_p and dnXOffset_p input positions.
• A value of "0" is output at the dnYSpeedOut_s output.
Caution: Thus, a position step change at the master value end will
not be displayed at dnYSpeedOut_s!
TRUE Function is activated.
• According to the coupling mode parameterised in C05090, the
output signals follow the input positions, dnXPosIn_p and
dnXOffset_p.
GQ6WDWH
E;=HUR3RV
GQ<6SHHG2XWBV
GQ;6SHHG2XWBV
GQ;$FW3RVBS
/B/G6\QF2SHUDWLRQ
GQ;3RV,QBS
GQ;2IIVHWBS
E(QDEOH
;$[LV'DWD
<$[LV'DWD
2IIVHW
;
<
&
&
&
&
&
&
&
&RXSOLQJIDFWRU;
&RXSOLQJIDFWRU<
& &RXSOHPHDVXULQJV\VWHP;DQG<
&
&\FOH<
&
&\FOH;
&