5 Function blocks
5.93 L_LdMPot - master value adjustment
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.93 L_LdMPot - master value adjustment
This FB serves to execute a master value adjustment.
Inputs
Function library: LenzeLineDrive
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
bEnable
BOOL
Activate master value adjustment
FALSE Master value adjustment is/will be deactivated.
•Output dnSpeedOut_s is braked to standstill via the disable ramp,
if required.
TRUE Master value adjustment is activated.
bJogPositive
BOOL
Adjustment in positive traversing direction
FALSE Output dnSpeedOut_s is braked to standstill via the deceleration
ramp.
TRUE Output dnSpeedOut_s is led to positive speed (C05122) via the start-
up ramp.
bJogNegative
BOOL
Adjustment in negative traversing direction
FALSE Output dnSpeedOut_s is braked to standstill via the deceleration
ramp.
TRUE Output dnSpeedOut_s is led to negative speed (C05123) via the start-
up ramp.
AxisData Machine parameters
• For accepting the machine parameters of the drive/motor, connect this input
with the output DI_AxisData of the SB LS_DriveInterface.
• The machine parameters of a master drive can be displayed with the
FB L_SdSetAxisData
. In this case, the FB output AxisData must be connected to
this input. ( 510)
E%XV\
GQ6SHHG2XWBV
/B/G03RW
E-RJ1HJDWLYH
$[LV'DWD
E(QDEOH
E-RJ3RVLWLYH
'HFHOHUDWLRQ
5DPS
0RWRUSRWHQWLRPHWHURII
&
&
&
n
p
on
o
p
$FFHOHUDWLRQ
p
on
1HJDWLYHVSHHG
&
&
3RVLWLYHVSHHG
&
& 6SHHGXQLW
& 5HIHUHQFHVSHHG