User guide

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05 251
5 Function blocks
5.64 L_DevApplErr - error tripping
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.64 L_DevApplErr - error tripping
This FB is used for error handling in the application.
Via the 8 boolean inputs up to 8 different application error messages with parameterisable mo-
dule ID, error ID and error response can be released by the application.
•In contrast to FBL_DevApplErrFix
the module ID; error ID, and the error response of this FB can
be set via parameters and not via inputs.
If more than 8 application error messages are required, the FB can be instanced.
If several inputs are set to TRUE at the same time, the input with the lowest number will activate
the error message.
Inputs
Function library: LenzeDevice9400
Runtime software licence: Motion Control HighLevel Motion Control TopLevel
Identifier/data type Information/possible settings
bError1
BOOL
Input for error message 1 (highest priority)
FALSETRUE Error condition 1 is met and the parameterised application error
message is output by the operating system.
FALSE Error condition 1 is no longer met.
... ...
bError8
BOOL
Input for error message 8 (lowest priority)
FALSETRUE Error condition 8 is met and the parameterised application error
message is output by the operating system.
FALSE Error condition 8 is no longer met.