2Introduction
2.4 Further objects of an interconnection
22
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.4.3 Variable
Variables can be used for a cross-task value exchange and for the use of constant values. The use of
significantly named variables can make the interconnection more clear and easier to maintain.
If you assign the "safe against mains failure" property to a variable, the value of the variable re-
mains stored even after mains switching.
A variable can be inserted exactly once with an input (for value assignment) into the intercon-
nection and as often as required with an output (for read access).
[2-5] Example 1: Variable "SetValue1_s" on the left with input for value assignment and on the right with output for reading ac-
cess
[2-6] Example 2: Variables (with output) for the constant values 100 %, 0 %, -100 % as well as FALSE and TRUE
Note!
Variables are only assigned at the end of the task cycle! Thus, the variable value will only
be effective in the next task cycle!