5 Function blocks
5.2 L_CamContactor - cam group with switch-on and switch-off dynamisation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
Parameter
dnHysteresePos_p
DINT
From library V01.02.xx.xx
Switching hysteresis in [increments]
Is added to the switching hysteresis set in C05523.
ContactorData
From library V01.02.xx.xx
Cam data
Interface for optional acceptance of the contactor data from the
FB L_CamSetContDataPDO
or FB L_CamSetContDataSDO. These two FBs enable
the direct selection of contactor data via inputs/PDOs or codes/SDOs (e.g. from a
master control).
If contactor data are pending at this input, these will be used instead of the con-
tactor data available in the cam data.
Identifier/data type Value/meaning
bOut
BOOL
Cam status of the cam track selected
FALSE Cam switched off.
TRUE Cam switched on.
dnCycleLength_p
DINT
From library V01.01.xx.xx
Cycle in [increments]
C05528 indicates the cycle in the real unit of the machine.
bError
BOOL
"Error" status
TRUE An error has occurred (group signal).
For details see display parameters C05529.
AxisData Machine parameters
Via this output the machine parameters used by the FB can be easily transferred
to subsequent FBs.
Parameter Possible settings Information
C05520/1 String of digits Position unit
•Read only
C05520/2 String of digits Designation of the measuring sys-
tem
•Read only
C05521 -1000.000 ms 1000.000 Switch-on position displacement
Initialisation: 0.000 ms
C05522 -1000.000 ms 1000.000 Output position displacement
Initialisation: 0.000 ms
C05523 -214748.3647 Unit 214748.3647 Hysteresis for switching threshold
If the input position is not stable
and the output bOut oscillates.
C05524 Track switch-over mode
0 In the zero crossing/cycle Lenze setting
Use for modulo traversing range.
1 Immediately This setting should be used for a li-
mited traversing range.
Identifier/data type Information/possible settings