User guide

Mechanical installation
Mounting variant
5
EDK84AZESRx DE/EN/FR/ES/IT 2.0
55
l
H1_MechINS−FE−Filt_84_Var_Mont_Schritte
Mounting steps
Device size GG1 − GG3 Device size GG4 − GG5
E84AZESR008 E84AZESR021
Proceed as follows for installation:
1. Prepare M5 threaded holes on the mounting plate and equip them with screws and
washers.
Two M5 screw and washer assemblies or M5 hexagon socket screws with washers
for the filter.
Two M5 screw and washer assemblies or M5 hexagon socket screws with washers
for the standard device.
Do not yet tighten the screws.
2. Remove the screw and washer assemblies from the filter to fix the standard device.
3. Mount the filter onto the prepared mounting plate.
Only tighten the screws hand−tight.
4. Mount the standard device onto the prepared mounting plate.
Observe the instructions in the documentation for the standard device.
Only tighten the screws hand−tight.
5. If necessary, preassemble additional units.
6. Align all units.
7. Screw all units onto the mounting plate.
Tightening torque: 3.4 Nm (30 lb−in)