Mounting steps
Device size GG1 − GG3 Device size GG4 − GG5
E84AZESR007 E84AZESR020
Proceed as follows for installation:
1. Prepare M5 threaded holes on the mounting plate and equip them with screws and
washers.
Use four M5 screw and washer assemblies or M5 hexagon socket screws with
washers.
Do not yet tighten the screws.
2. Mount the filter onto the prepared mounting plate.
Only tighten the screws hand−tight.
3. Loosen the two screw and washer assemblies to fix the standard device on the filter.
Two M5 × 14 mm screw and washer assemblies.
4. Mount the standard device onto the filter and tighten the screws.
Observe the instructions in the documentation for the standard device.
Tightening torque: 3.4 Nm (30 lb−in)
5. If necessary, preassemble additional units.
6. Align all units.
7. Screw all units onto the mounting plate.