Instructions Owner's manual
Electrical installation
Interfaces for peripheral devices
Cable fixing and strain relief
6
30
Lenze ¯ BA_c300 ¯ 2.0
6.4.4 Cable fixing and strain relief
Fasten the cable bundles to the device using cable ties.
The fastening points for cable ties for strain relief are located at the top and at the
bottom of the device, respectively.
c300_022
EL100−034
Fig. 6−4 Cable retention and strain relief
6.4.5 USB interface
Figure Connection Connection type Cable type
X4:
USB 2.0 connection
(max. load: 5 V/500 mA)
USB−A socket
USB cable with
USB−A plug
IPC001