Instruction Manual

5Diagnostics
5.3 Event of an error: Controller c300/p300 does not start
40
Lenze · Backup & Restore · Software Manual · DMS 1.3 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.3 Event of an error: Controller c300/p300 does not start
If Controller c300 or p300 does not start, the Lenze standard settings can be activated with the Reset
button.
How to activate the Lenze standard settings:
1. Switch off voltage supply.
2. Activate Reset button.
3. When the Reset button is activated, switch on voltage supply and keep the Reset button
pressed for at least 10 s.
If the Error LED (green/red) is blinking after this action, manual mains switching is
required.
The controller must be disconnected from the mains supply until all LEDs have gone off.