Safety Information

BST Testing (Shenzhen) Co.,Ltd. Report No.: BSTXD21052021096301SR
No.7, New Era Industrial Zone, Guantian, Baoan District, Shenzhen, Guangdong, China.
Tel: 400-882-9628 E-mail:christina@bst-lab.com Complaints hotline:86-755-26747756 http://www.bst-lab.com
Page 6 /
14
11 RESISTANCE TO HEAT
Parts of insulating material providing protection
against electric shock, retaining live parts in
position, ball-pressure test:
(see appended table) P
12 RESISTANCE TO FLAME AND IGNITION
External parts of insulating material preventing
electric shock glow-wire test 650 °C
(see appended table) P
13 FAULT CONDITIONS
13.2 Fault conditions: where diagram indicates fault
condition impairs safety, electronic components
have been short-circuited or disconnected
(see appended table) P
13.3 When operated under fault conditions the lamp P
- does not emit flames or molten material P
- does not produce flammable gases or smoke P
- live parts not accessible P
After the tests the insulation resistance with d.c.
1000 V complies with requirements of Cl. 8.1:
100M P
14 (16) CREEPAGE DISTANCES AND CLEARANCES
Creepage distances and clearances according to
IEC 61347-1
(see appended table) P
Conductive accessible parts according to IEC
60598-1
(see appended table) P
15 ABNORMAL OPERATION
Non-dimmable self-ballasted lamps are tested on a
dimmer or an electronic switch according the test
circuit shown in Figure 8
NA
Operate the lamp for 8 h at most onerous dimming
level
NA
When operated under abnormal operation the lamp
- does not catch fire NA
- does not produce flammable gases NA