Specifications
Table Of Contents
- Safety information
- Chapter 1. General information
- Chapter 2. Server setup road map
- Chapter 3. Product overview
- Chapter 4. Turning on and turning off the server
- Chapter 5. Configuring the server
- Chapter 6. Installing, removing, or replacing hardware
- Guidelines
- Removing the server cover
- Removing and reinstalling the front bezel
- Removing and reinstalling the PCI card bracket assembly
- Installing, removing, or replacing hardware
- Installing or removing a memory module
- Installing or removing the Ethernet card
- Installing or removing the RAID card
- Installing or removing the ThinkServer RAID 500 Upgrade Key for Advanced RAID
- Installing or removing the ThinkServer RAID 700 Battery
- Installing or replacing an optical drive
- Installing or removing a non-hot-swap hard disk drive
- Installing or replacing an internal RDX drive
- Installing or replacing a 2.5-inch solid-state drive
- Installing or replacing a hot-swap hard disk drive
- Installing or replacing a hot-swap redundant power supply
- Replacing the power distribution board and cage assembly
- Replacing the power conversion board
- Replacing the hot-swap hard-disk-drive backplane
- Replacing the non-hot-swap power supply assembly
- Replacing the cover presence switch
- Replacing the front panel board assembly
- Replacing the front system fan 1
- Replacing the rear system fan
- Replacing the heat sink and fan assembly
- Replacing the microprocessor
- Replacing the system board battery
- Replacing the system board
- Completing the parts replacement
- Chapter 7. Troubleshooting and diagnostics
- Chapter 8. Getting information, help, and service
- Appendix A. Notices
- Trademarks
- Important notes
- Polyvinyl Chloride (PVC) cable and cord notice
- Recycling information
- Particulate contamination
- Important WEEE information
- Restriction of Hazardous Substances Directive (RoHS)
- German Ordinance for Work gloss statement
- Export classification notice
- Electronic emission notices
- Eurasian compliance mark
- Index

mightrequiresometechnicalskillsortools,orrequestthatatechnicianinstalltheoptional-serviceCRU
underthetermsoftheapplicablewarrantyservicetypeforyourcountryorregion.
Non-CRUsmustbereplacedonlybytrainedservicetechnicians.
ThefollowingtableliststhemajorFRUsinyourserverandtheCRUidentificationinformation.Foracomplete
listingofFRUinformation,suchasFRUpartnumbersandsupportedservermodels,goto:
http://www.lenovo.com/serviceparts-lookup
Notes:
•BeforeservicingaLenovoproduct,ensurethatyoureadandunderstand“Safetyinformation”onpageiii
.
•UseonlypartsprovidedbyLenovo.
Description
Self-serviceCRUOptional-service
CRU
FrontpanelboardassemblyNoYes
Frontsystemfan
YesNo
Heatsinkandfanassembly
YesNo
Hot-swapharddiskdriveYesNo
Hot-swapharddiskdrivebackplane(availableinsomemodels)
NoYes
Hot-swapredundantpowersupply(availableinsomemodels)
YesNo
KeyboardYesNo
MemorymoduleYesNo
MicroprocessorNoYes
MouseYesNo
Non-hot-swappowersupplyassembly(availableinsomemodels)
NoYes
Opticaldrive
YesNo
PeripheralComponentInterconnect(PCI)card(availableinsomemodels)
YesNo
PowerconversionboardNoYes
Powerdistributionboardandcageassembly(availableinmodelswith
hot-swapredundantpowersupplies)
NoYes
Rearsystemfan
YesNo
Systemboard
NoNo
Systemboardbattery
YesNo
ThinkServerRAID500UpgradeKeyforAdvancedRAID(availableasan
option)
YesNo
ThinkServerRAID700Battery(availableasanoption)
NoYes
Hot-swaphard-disk-drivestatusLEDs
Thistopicappliesonlytoservermodelswithhot-swapharddiskdrives.
Note:Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.
Eachhot-swapharddiskdrivehastwostatusLEDsonthefront.Unlockandopenthefrontdoortoaccess
theharddiskdrivesandviewthestatusLEDs.
28ThinkServerTS440HardwareMaintenanceManual