Manual
Table Of Contents
- Preface
- Chapter 1. Overview
- Chapter 2. Installation
- Chapter 3. Working with Client Security Solution
- Chapter 4. Working with ThinkVantage Fingerprint Software
- Chapter 5. Working with Lenovo Fingerprint Software
- Chapter 6. Best Practices
- Deployment examples for installing Client Security Solution
- Switching Client Security Solution modes
- Corporate Active Directory rollout
- Standalone Install for CD or script files
- System Update
- System Migration Assistant
- Generating a certificate using key generation in the TPM
- Using USB fingerprint keyboards with 2008 ThinkPad notebook computer models (R400/R500/T400/T500/W500/X200/X301)
- Appendix A. Special considerations for using the Lenovo Fingerprint Keyboard with some ThinkPad notebook models
- Appendix B. Synchronizing password in Client Security Solution after the Windows password is reset
- Appendix C. Using Client Security Solution on a reinstalled Windows operating system
- Appendix D. Using the TPM on ThinkPad notebook computers
- Appendix E. Notices
- Glossary

•Atmel-ThinkPadT60/R60/X60/X300,ThinkCentreM57
•Intel-ThinkPadT500/R500/X200/X301
•STMicro-ThinkPadT410/T510/X201/T420/T520/X220,ThinkCentreM90
•Winbond-ThinkCentreM58
TheseTPMshavedifferentcharacteristicswhentheyenterlockoutmode,asdescribedbelow:
AtmelTPM:
•Nolockoutduringtherst15badpasswordattempts
•The16thbadpasswordattemptresultsinalockoutperiodof1.1minutes
•Then,nolockoutduringthenext15badpasswordattempts
•Thenextlockoutperiodis2.2minutes
•Eachlockoutperioddoubles,aftereachbatchof15badpasswordattempts,uptoamaximumlockout
periodof4.7hours
•Lockoutisresetifthecomputeristurnedoff
IntelTPM:
•Nolockoutduringtherst100badpasswordattempts
•The101stbadpasswordattemptresultsinalockoutperiodof16seconds
•Eachsubsequentbadpasswordattemptresultsinalockoutperiodtwiceaslongasthepreviouslockout
period,withoutamaximumlockoutperiod
•Thebadpasswordcounterdecreasesbyoneeachhour,untilitdecreasestozero
STMicroTPM:
•Nolockoutduringtherst40badpasswordattempts
•The41stbadpasswordattemptresultsinalockoutperiodofthreeseconds
•Eachsubsequentbadpasswordattemptresultsinalockoutperiodtwiceaslongasthepreviouslockout
period,withamaximumlockoutperiodoftwohours
WinbondTPM:
•Therstbadpasswordattemptresultsinalockoutperiodof0.25millisecond
•Eachsubsequentbadpasswordattemptresultsinalockoutperiodtwiceaslongasthepreviouslockout
period,withamaximumlockoutperiodof14hours
Note:Ittakes13badattemptstoreachalockoutperiodofonesecond.
•After24hours,thebadpasswordcounterisresettozero
74ClientSecuritySolution8.3DeploymentGuide