Personal Computer User Manual
Table Of Contents
- Important safety information
- Chapter 1. Product overview
- Chapter 2. You and your computer
- Chapter 3. Security
- Chapter 4. Installing or replacing hardware
- Handling static-sensitive devices
- Installing or replacing hardware
- Installing external options
- Removing the computer cover
- Removing and reinstalling the front bezel
- Installing or replacing a PCI card
- Installing or replacing a memory module
- Installing or replacing the optical drive
- Replacing the card reader
- Replacing the power supply assembly
- Replacing the heat sink and fan assembly
- Replacing the primary hard disk drive
- Replacing the secondary hard disk drive
- Replacing the front fan assembly
- Replacing the rear fan assembly
- Replacing the keyboard or mouse
- Completing the parts replacement
- Chapter 5. Recovery information
- Chapter 6. Using the Setup Utility program
- Chapter 7. Configuring RAID
- Chapter 8. Updating system programs
- Chapter 9. Troubleshooting and diagnostics
- Chapter 10. Getting information, help, and service
- Appendix A. Notices
- Appendix B. Regulatory information
- Appendix C. WEEE and recycling information
- Index

Chapter7.ConguringRAID
ThischapterprovidesinformationabouthowtocongureRedundantArrayofIndependentDisks(RAID)
foryourcomputer.
Note:TheinformationaboutconguringRAIDinthischapterisapplicableonlyforaWindowsenvironment.
ForinformationaboutconguringRAIDinaLinuxenvironment,contactyourLinuxsoftwareprovider.
RAIDLevel
YourcomputermusthavetheminimumnumberofSATAharddiskdrivesinstalledforthesupportedlevelof
RAIDbelow:
•RAIDLevel0–Stripeddiskarray
–Twoharddiskdrivesminimum
–Betterperformancewithoutfaulttolerance
•RAIDLevel1–Mirroreddiskarray
–Twoharddiskdrivesminimum
–Improvedreadperformanceand100%redundancy
Toinstallasecondaryharddiskdrive,referto“Replacingthesecondaryharddiskdrive”onpage42.
ConguringthesystemBIOStoenableSATARAIDfunctionality
ThissectiondescribeshowtocongurethesystemBIOStoenableSATARAIDfunctionality.
Note:Usethearrowkeysonthekeyboardtomakeselections.
ToenableSATARAIDfunctionality,dothefollowing:
1.StarttheSetupUtilityprogram.See“StartingtheSetupUtilityprogram”onpage59.
2.SelectDevices➙ATADriveSetup.
3.SelectCongureSATAasandpressEnter.
4.SelectRAIDModeandpressEnter.
5.PressF10tosavethenewsettingsandexittheSetupUtilityprogram.
CreatingRAIDvolumes
ThissectiondescribeshowtousetheIntelMatrixStorageManageroptionROMcongurationutilityto
createRAIDvolumes.
TocreateRAIDvolumes,dothefollowing:
1.PressCtrl+IwhenpromptedtoentertheIntelMatrixStorageManageroptionROMcongurationutility
duringthecomputerstartup.
2.UsetheupanddownarrowkeystoselectCreateRAIDVolumeandpressEnter.
3.TypeaproperRAIDVolumenameintheNameeldandpressTab.
4.UsethearrowkeystoselectaRAIDlevelintheRAIDLeveleldandpressTab.
5.Ifappropriate,usethearrowkeystoselectaStripeSizeintheStripeSizeeldandpressTab.
6.TypeavolumesizeintheCapacityeldandpressTab.
©CopyrightLenovo2011
65










