Computer Hardware User Manual

CAUTION:
Theheatsink(s)andmicroprocessor(s)mightbeveryhot.Turnofftheserverandwaitthreetove
minutestolettheservercoolbeforeremovingtheservercover.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Note:Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.
Toreplacethesystemboard,dothefollowing:
1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectall
powercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedtotheserver.
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.
3.Removethehot-swapredundantpowersupplies.See“Replacingahot-swapredundantpower
supply”onpage102
.
4.Removetheservercover.See“Removingtheservercoveronpage69.
5.Removethecoolingshroud.See“Removingandreinstallingthecoolingshroud”onpage73.
6.Recordthecomponentlocations,cableconnections,andcableroutingintheserver.
7.Removeallmemorymodules.See“Removingamemorymodule”onpage80.
8.Removethetworisercardassemblies.See“Replacingtherisercardassembly1”onpage142.
9.RemovetheTPMifoneisinstalled.See“RemovingtheThinkServerTrustedPlatformModule”on
page98.
10.RemovetheTMMPremiumifoneisinstalled.See“RemovingtheTMMPremium”onpage95.
11.Removethesystemboardbattery.See“Replacingthesystemboardbattery”onpage144.
12.Disconnectallthesystemfancablesfromthesystemboard.Then,holdthetwosystemfancages
andliftthemstraightupandoutofthechassis.
ID
Mem
CPU
PSU
Figure117.Removingthetwosystemfancageswiththesystemfans
Chapter6.Installing,removing,orreplacinghardware147