Computer Hardware User Manual

FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
SeeChapter7“Partslisting,RS210Types6531,6532,6533,and6534”onpage175todeterminewhich
componentsarecustomerreplaceableunits(CRU)andwhichcomponentsareeldreplaceableunits(FRU).
Ifanactionstepisprecededby“(Trainedservicetechnicianonly),thatstepmustbeperformedonlyby
atrainedservicetechnician.
MemoryLoggingLimitReached
forDIMMnStatusonMemory
SubsystemDIMMnStatus.(n=DIMM
number)
ErrorThememorylogginglimit
hasbeenreached.
1.Updatetheserverrmwareto
thelatestlevel.
Important:Somecluster
solutionsrequirespeciccode
levelsorcoordinatedcode
updates.Ifthedeviceispart
ofaclustersolution,verify
thatthelatestlevelofcode
issupportedforthecluster
solutionbeforeyouupdatethe
code.
2.ReseattheDIMMsandrunthe
DSAmemorytest.
3.ReplaceanyDIMMthatis
indicatedbyaliterrorLED.
MemoryDIMMCongurationError
forDIMMnStatusonMemory
SubsystemDIMMnStatus.(n=DIMM
number)
Error
ADIMMcongurationerror
hasoccurred.
MakesurethatDIMMsare
installedinthecorrectsequence
andhavethesamesize,type,
speed,andtechnology.
SensorDIMMnTemphastransitioned
tocriticalfromalessseverestate.(n
=DIMMnumber)
ErrorAsensorhaschangedto
Criticalstatefromaless
severestate.
1.Makesurethatthefansare
operating,thatthereareno
obstructionstotheairow,that
theairbafesareinplaceand
correctlyinstalled,andthat
theservercoverisinstalled
andcompletelyclosed.
2.Ifafanhasfailed,complete
theactionforafanfailure.
3.ReplaceDIMMn.
(n=DIMMnumber)
Chapter4.Diagnostics37